Generate fault trees, bow-ties, event trees, reliability block diagrams, GSN arguments and Markov models from Power BI data with the Ataytis Assurance visual.

Ataytis Assurance · Reliability Block Diagram

Reliability block validation

The rules a reliability block diagram is checked against and their severity, and the messages they produce with how to fix them.

Rules

RuleSeverity
A path runs from the input to the outputError
Nothing leads into the inputError
Nothing follows the outputError
The m of an m-out-of-n block is a whole number of 1 or moreError
m is no more than nError
No cycles, apart from dependenciesError
At most one input and one outputWarning
Every block except the output leads somewhereWarning
n matches the blocks connected to an m-out-of-n blockWarning
Node and relationship types are recognisedWarning
Every block is joined to the diagramWarning

None of these stops the diagram drawing. A missing Node ID mapping does. A reliability block diagram has no advisories.

Messages and fixes

MessageFix
No complete path connects the input side to the output side.Check Connected Node ID along the path. If the input and output are reported as well, the table names the previous block: change Reads as on the Data Mapping tab.
An input is where the diagram starts, so nothing may lead into it. Remove the incoming connection, or make this a component.Remove the row that leads into the input, or change its Node Type.
An output is where the diagram stops, but this one carries on into another block. Remove the onward connection, or make this a component if the path continues past it.Clear Connected Node ID on the output's row.
Nothing leaves this block, so no path through it reaches the output. Connect it onward, or make it the output if the diagram ends here.Give the block a Connected Node ID, or make it the Output.
An m-out-of-n block needs at least one of its inputs, and this one asks for 0.Set Vote Threshold to a whole number of 1 or more.
This block asks for 4 of 3 inputs, which can never be met. The number required cannot exceed the number available.Correct Vote Threshold or Vote Input Count.
This block says it has 3 inputs, but 2 are connected to it. Correct the count, or connect the blocks it is missing.Correct Vote Input Count, or connect the missing blocks.
Input occurs 2 times.Keep one input. A second output gives the same message for Output.
The graph contains a directed cycle that is invalid for this mode.A block leads back to one before it. Check Connected Node ID, or use a Dependency where one block affects another.
A relationship references a node that is not present.A Connected Node ID names a block with no row of its own. Add its row, or correct the identifier. One that differs only by spaces is named in the message.
The diagram contains 2 disconnected components.Some blocks are not joined to the rest. Check Connected Node ID.

An unrecognised node or connection type is reported as, for example, "Pump" is not a recognised node type. Map the value under Node type values or Relationship values on the Data Mapping tab. Names and numbers in all these messages come from your data.